H O T F I X 2 F O R A B B A / E 2 . 3 0 G Installationprerequisite : ABBA/E Software 2.30G Related ticket : ---- Contents of the floppy : FLWMULTI.IRD FRACK.IRD INIT.IRD PERMAN.IRD VERSION.DAT Hotfix 2 contains Hotfix 1 Installation : - Reset the Rho Controller, no power on, only mainswitch on - Upload original Files from Version 2.30G to your Harddisk (Backup for safety) - Download the files to the Rho Controller - Reset the Rho Controller Description : - on the second Newgrip apears a crash at the wall, if the unit is not in the same segment as the newgripstation. - if the Bow in backposition signal was missing at the second crash on a unit the gripper was opening, and lost the cartridge. - If a crash apears on the Tower or Rack, there was no move backward. The System have to be reseted. - Correction in Handling, GET Offset against PUT KONFIG.DAT (Y_GET_LW) Example: 500,200 500 is for GET and PUT, when no second value exists. 200 is a GET OFFSET - The DLT Tape will was moved (z) not so high as before : - nach dem zweiten Ausrichen wurde an die Verkleidung gefahren, wenn die Unit nicht im gleichen Bereich wie Ausrichtsatation ist. - bei fehlendem Bgel hinten Signal wurde beim zweiten crash an der Unit die Kassette losgelassen. - Bei crash am Turm oder Rack wurde nicht zurueckgefahren. Steuerung musste resettet werden. - Korrektur Handling, GET Versatz Laufwerk zu PUT KONFIG.DAT (Y_GET_LW) Bsp.: 500,200 500 wirkt auf GET und PUT 200 wirkt als GET Versatz - Das DLT Tape wird beim GET nicht mehr so hoch (Z) angehoben EMASS-Grau Storage Systems, 08.01.99